Information on the IP-protection classes
- IP54
The ingress of dust is not totally prevented, but it does not affect operation or safety. Protection against splash water from all directions.
Test time: 10 min. / 10l / min.
- IP55
The ingress of dust is not totally prevented, but it does not affect operation or safety. Protection against splash water from all directions.
Test time of 3 min. / 12,5L / min.
- IP66
Protection against ingress of dust at a lower housing pressure of 20 mbar and protection against strong jets of water from all directions.
Test time of at least 3 min. / 100 l / min.
- IP69
Safe against high pressure cleaner. Water jet 100 bar / 80 degrees.
Test time 30 sec. per abutting edge between door casing and door lock.
- IP67
Protection against ingress of dust at a lower housing pressure of 20 mbar and protection against water entry during temporary submersion.
Test time max. 1 h, water depth max. 1 m.
- IP68
Protection against ingress of dust at a lower housing pressure of 20 mbar and protection against water ingress in continuous immersion.
Test time over 1 h, water depth over 1 m.